DELL EMC VMAX3 Solutions (SA) E20-807 Exam Dumps Online | DumpsBase
E20-807 Expert – VMAX All Flash and VMAX3 Solutions Exam, as an expert DELL EMC exam online, is for Expert – VMAX All Flash and VMAX3 Solutions 2.0 certification. Most candidates are registering for their DELL EMC E20-807 exam. To help all the candidates prepare for DELL EMC VMAX3 Solutions (SA) E20-807 Exam well, DumpsBase have updated DELL EMC E20-807 exam dumps with great exam questions and answers. DELL EMC VMAX3 Solutions (SA) E20-807 Exam Dumps Online V9.02 are written by the top certified experts, who have more than 10 years' experience in providing EMC E20-807 exam dumps, which are really helpful for getting VMAX3 Solutions (SA) certified. We ensure that the great DELL EMC E20-807 exam dumps should be the best materials for preparation.
How to complete Expert – VMAX All Flash and VMAX3 Solutions 2.0 certification?
Most candidates come for E20-807 Expert – VMAX All Flash and VMAX3 Solutions Exam, because they want to complete Expert – VMAX All Flash and VMAX3 Solutions 2.0 certification. This certification benefits any professional responsible for performance analysis of VMAX All Flash and VMAX3 arrays, design and implementation of VMAX security, multi-site SRDF, SRDF/Metro, FAST.X.and Non-disruptive Migrations(NDM). Besides taking and passing DELL EMC E20-807 exam, what other exams and certifications are required for Expert – VMAX All Flash and VMAX3 Solutions 2.0 certification?
We have checked, to complete your Expert – VMAX All Flash and VMAX3 Solutions 2.0 certification, you must:
1. Achieve one of the following Associate level certifications
● Associate - Information Storage and Management Version 1.0
● Associate - Information Storage and Management Version 2.0
● Associate - Information Storage and Management Version 3.0
2. Achieve one of the following Specialist level certifications
● Specialist – Systems Administrator, VMAX3 Solutions Version 1.0
● Specialist – Implementation Engineer, VMAX3 Solutions Version 1.0
● Specialist – Technology Architect, VMAX3 Solutions Version 1.0
● Specialist – Implementation Engineer, VMAX All Flash and VMAX3 Solutions Version 2.0
● Specialist – Systems Administrator, VMAX All Flash and VMAX3 Solutions Version 2.0
● Specialist - Implementation Engineer, PowerMax and VMAX Family Solutions Version 1.0
3. Pass the following Expert exam on or after May 06, 2016:
● E20-807 Expert - VMAX All Flash and VMAX3 Solutions Exam
What are the DELL EMC E20-807 exam topics for learning?
If now you are preparing for E20-807 Expert - VMAX All Flash and VMAX3 Solutions Exam, you need to mater the E20-807 exam topics for good leanring. DELL EMC E20-807 exam is a qualifying exam for all VMAX All Flash and VMAX3 Solutions Expert tracks, including, Technology Architect, Implementation Engineer, and Storage Administrator. The E20-807 exam topics include:
● VMAX All Flash and VMAX3 Performance (36%)
● VMAX All Flash and VMAX3 Security Concepts (14%)
● VMAX All Flash VMAX3 Multi-site SRDF Solutions (16%)
● VMAX All Flash and VMAX3 SRDF/Metro Solutions (12%)
● VMAX All Flash and VMAX3 FAST.X Solutions (15%)
● VMAX All Flash and VMAX3 Non-disruptive Data Migration (NDM) (7%)
If any possible to get DumpsBase E20-807 free dumps for checking?
DELL EMC VMAX3 Solutions (SA) E20-807 Exam Dumps Online from DumpsBase are great, which are designed to test your skills in E20-807 exam topics. Dumpsbase EMC VMAX3 Solutions (SA) E20-807 exam dumps can guarantee you pass the test in the first attempt. Most candidates want to check E20-807 free dumps online, we here will share E20-807 free dumps questions for reading and checking:
What is the best practice for FA utilization in a VMAX3 array?
A. 50% busy with two engines
B. 50% busy with more than two engines
C. 50% busy with one engine
D. 50% busy with two or more engines
Answer: A
What is a key difference between SRDF/Metro and SRDF/S?
A. SRDF/Metro: R1 devise is host accessible, R2 is red-only
SRDF/S: R1 is host accessible, R2 is write disabled
B. SRDF/Metro: R1 and R2 devices are host accessible at the same time
SRDF/S: R1 devices are host accessible, R2 devices are write disabled
C. SRDF/Metro: R2 can be larger than R1
SRDF/S R2 cannot be larger than R1
D. SRDF/Metro: Requires a third array for any witness functionality
SRDF/S: Does not require a third array
Answer: B
SRDF/Metro has been deployed.
What is the state and external identity of the R2 devices after initial synchronization has completed?
A. State: Read/Write
Identity: R1 Identity
B. State: Read/Write
Identity: Original Identity
C. State: Write Disabled
Identity: Original Identity
D. State: Write Disabled
Identity: R1 Identity
Answer: A
What is requirement when setting up a Composite Group (CG) for SRDF/Star in an open systems environment?
A. Composite Group is created with the Star Build CG action
B. Composite Group is created with the type set to ANY
C. Recovery group assignments should match the recovery groups defined in the Star Options file
D. Names assigned to RDF groups match the site names in the Star Options file
Answer: C
What is a Dell EMC recommended best practice when connecting CloudArray to a VMAX3?
A. Hosts should average at least 2,500 IOPS
B. Internal SRP should be used
C. Host I/O limits should be used
D. Host I/O limits should not be used
Answer: B
SRDF/Metro has been deployed between two data centers. SRDF/Metro is operating normally. Maintenance tasks at the R1 data center require the array to be offline.
Which SRDF operation should be executed on the Metro RDF pairs to facilitate the planned outage without affecting application I/O?
A. Failover
B. Split with bias set to R2
C. Suspend with bias set to R2
D. Swap
Answer: A
FAST.X needs to be configured on a VMAX3 array to access LUNs on an XtremIO X-Brick. In addition, existing data on the LUNs has to be preserved and made available for host access.
How can this be accomplished?
A. By externally provisioning the LUNs
B. By incorporating the LUNs
C. By zoning the host HBAs to the VMAX3 array FE ports
D. By zoning the host HBAs to the VMAX3 array DX ports
Answer: B
SRDF/A MSC has been configured between two sites. There are two VMAX3 arrays at the source site and two VMAX3 arrays at the target site. An SRDF/A MSC trip event has occurred.
What happens if the Receive Delta Set on one of the target arrays is incomplete?
A. Partial Receive Delta Set data is applied
B. Receive Delta Set data is discarded
C. Session is marked as Cleanup required
D. Session is marked as Partitioned
Answer: B
What is an accurate statement about D@RE on a VMAX3 array?
A. FASTX external storage is not encrypted
B. System metadata is never encrypted
C. Existing data can be encrypted in place
D. Global Memory always encrypted
Answer: C
What is the effective queue depth of a device mapped to a host with eight paths on a VMAX3 array?
A. 64
B. 128
C. 256
D. 512
Answer: B