Passing the HCSA-Presales-Digital Power H19-311-ENU exam can be a daunting task, but it doesn’t have to be. With the right resources and preparation, you can confidently pass the H19-311-ENU exam and achieve your professional goals. One key to success is using the most updated H19-311-ENU exam dumps that have been completed by top experts. These questions cover all of the actual exam topics and contents, ensuring that you are well-prepared for what you will encounter on test day. By using the H19-311-ENU exam dumps and preparing with these updated exam questions, you will be able to pass the HCSA-Presales-Digital Power H19-311-ENU exam with confidence and achieve your desired outcome.

Choose to read Huawei H19-311-ENU free demo questions before getting the updated dumps:

1. If the UPS5000-A-400/500K is configured with a set of 40 12V batteries, how many battery inspection instruments do you need to configure? ( )

2. Does the FusionModule800 channel have a skylight?

3. The type of circuit breaker used in the sub-circuit of the PDU8000 precision power distribution cabinet. ( )

4. What is the maximum IT load supported by the FusionModule2000 integrated UPS? ( )

5. Which of the following is the refrigerant type of Huawei NetCol in-line air-cooled air conditioner ( )?

6. Regarding the Fusion module surveillance camera, which of the following statements is false? ( )

7. Compared with the chilled water scheme, which of the following is not an advantage of AHU ( )

8. The output power factor of UPS2000-G-(6K-20K) is ( ), which is suitable for new IT loads and significantly improves the load capacity of the system.

9. Huawei iManager NetEco6000 can be accessed by Huawei's ( ) system

10. The single cooling capacity range of the water-cooled centrifugal unit is:

11. The cell of Huawei Smartli lithium battery is ( )

12. Is the channel type of the typical configuration of FusionModule800 a cold aisle or a hot aisle? ( )

13. What are the incoming line methods supported by UPS5000-A-400/500K? ( )

14. At which of the following voltages the lead-acid battery is already in a dangerous state ( )

15. Which are standard configurations in the typical configuration of FusionModule800? (

16. The NetEco6000 management system supports access to third-party equipment to achieve centralized management of the computer room; then, when monitoring which of the following equipment is connected to third-party equipment,

it is necessary to pay the RM bill and report the third-party equipment access fee? (

17. In FusionModule2000, how to adapt the skylight when the column occupies the closed passage space in the scene around the column?

18. When the NetEco management system is sold in the market, which of the following situations does not need to submit RM to the management system RAT for decision-making? ( )

19. Fusionmodule2000 IT cabinet seismic rating? ( )

20. Which of the following statements is false about surveillance cameras?

21. What is the static load of the FusionModule2000 cabinet in KG?

22. What are the ways of piping in FusionModule800? ( )

23. The maximum charging capacity of UPS5000-E is ( )

24. The row-level chilled water intelligent temperature control product NetCol 5000-C032H adopts the form of running pipes ( )

25. The UPS used by FusionPower (prefabricated power module) is ( ).

26. When the single cell voltage in the battery pack reaches ( ), it means that the battery pack is already in a risky state

27. The minimum ambient temperature used by FusionModule800 and FusionModule500 is ( ).

28. UPS2000-G 1~3kVA supports ( ) parallel.

29. UPS2000-G 6~20kVA maximum support ( ) parallel, good scalability.

30. When a system is configured with a battery backup time of 15 minutes, the discharge termination voltage of the battery cell should be selected ( )

31. Among the following models, the one with the widest input frequency range is ( )

32. For the UPS5000-A system, which of the following battery configurations is unreasonable: ( ) (multiple choice)

33. FusionModule2000 maximum number of counters ( )

34. What is the minimum outdoor ambient temperature that the FusionModule800 air conditioner can support? ( )

35. FusionModule500&FusionModule800 display brand optional ( )

36. How many cabinets can a single row of FusionModule2000 support? ()

37. UPS5000-A-400/500K can support up to ( ) parallel machine, with good scalability. ()

38. "Data Center Design Specifications" GB50174-2017 stipulates that when selecting a site, a cooling data center should have sufficient water sources.

39. UPS5000-E only needs to select ( ), it can easily realize 2N power supply system, and the operation is simple and convenient. .

40. The NetEco management system supports dispatching corresponding work orders for a certain alarm to track the entire processing process.

What type of work order is this? (


 