Are you looking for real exam resource to prepare for VMware VCAP-NV Design 2020 certification 3V0-41.19 exam? VMware 3V0-41.19  exam tests your ability to gather customer requirements, risks, constraints, and assumptions, and use that information to make design recommendations for NSX-T Data Center 2.4 solutions. We have released new 3V0-41.19 dumps questions to help you prepare for 3V0-41.19 exam and achieve your VMware VCAP-NV Design 2020 certification successfully.

Check VMware VCAP-NV Design 2020 certification 3V0-41.19 free dumps first

1. Which NSX-T feature is used to allocate the network bandwidth to business-critical applications and to resolve situations where several types of traffic compete for common resources?

2. An architect is helping an organization with the Physical Design of an NSX-T Data Center solution and resolving a network throughput bottleneck.

This information was gathered during a workshop:

- A VM running a business critical application Is peaking at ~5Gbps

- Current host uplink is configured as Active/Standby with two 10Gb NICs.

- The installed server NIC model does not support GENEVE offload.

- All VM traffic is East/West.

- The business critical application VM communicates with multiple client VMs.

Which should the architect recommend to improve vSphere VM throughput?

3. Which three must be taken into consideration when creating a Logical Design for a planned migration? (Choose three.)

4. An architect is helping an organization with the Logical Design of an NSX-T Data Center solution.

This information was gathered during the Assessment Phase:

- Maximum performance and availability is required between the physical and virtual network.

- Load Balancing service is required for back-end web servers.

- NAT is required.

Which should the architect include in their design?

5. Which is associated with the Discover Task of the Engagement Lifecycle?

6. An NSX-T architect is working with a customer who wants to improve performance and future-proof

their workloads with a multi-site architecture.

A current-state analysis captured this information:

- Latency between sites Is 160ms.

- Bandwidth is 2Gbps.

- The MTU is 1600.

What two VMware design recommendations should the architect recommend to the organization to achieve future-proofing? (Choose two.)

7. An architect is helping an organization with the Logical Design of an NSX-T Data Center solution.

This information was gathered during the Assessment Phase:

- There Isn't much budget available for a new off-shore site.

- The new site is decentralized and no communication with the main data center is required.

- The design will need to cater for availability, upgrades, and failure scenarios.

Which three should the architect recommend In their design? (Choose three.)

8. Which three assessment findings are part of a Conceptual Design? (Choose three.)

9. An architect is helping an organization with the Physical Design of an NSX-T Data Center solution.

This information was gathered during a workshop:

- Some workloads should be moved to a Cloud Provider.

- Extend network's VLAN or VNI across sites on the same broadcast domain.

- Enable VM mobility use cases such as migration and disaster recovery without IP address changes.

- Support 1500 byte MTU between sites.

Which should the architect include in their design?

10. An architect is helping an organization with the Logical Design of an NSX-T Data Center solution.

This information was gathered during the Assessment Phase:

- Customer Is concerned with NSX Manager availability.

- 3 cabinets/racks are available in the data center.

- No integration with 3rd party solution is required.

- There is no budget for physical equipment acquisition.

- The 3 cabinets/racks do not share the same L2 domain.

Which three should the architect include in their design to address the customer's concern with NSX Manager availability? (Choose three.)

11. An architect is helping an organization with the Logical Design of an NSX-T Data Center solution.

During discussions about Centralized Services NAT running on Tier-1 or Tier-0 LR the customer made these requests:

- Services contain stateful services.

- Services should be in high availability mode.

Which two should the architect include in their design? (Choose two.)

12. An architect is helping an organization with the Physical Design of an NSX-T Data Center solution.

This information was gathered during the Assessment Phase:

- Deployment will be a brownfield vSphere environment.

- A smooth transition for deployment is required.

Which two should the architect include in their design? (Choose two.)

13. An architect is helping an organization with the Physical Design of an NSX-T Data Center solution.

This information was gathered during a workshop:

- There are six hosts and hardware has already been purchased.

- Customer is planning a collapsed Management/Edge/Compute cluster.

- Each host has two 10Gb NICs connected to a pair of ToR switches.

- There should be no single point of failure in any proposed design.

Which virtual switch design should the architect recommend to the organization?

14. An architect is helping an organization with the Physical Design of an NSX-T Data Center solution.

This information was gathered during a workshop about ESXi Host networking:

- A total of 50 ESXI hosts to be configured as Transport Nodes.

- All ESXi hosts have a dedicated 2 x Intel 10Gbps Physical Network adapter for the Overlay Traffic.

To achieve low latency, high throughput, redundancy, and performance, which two NIC teaming policies should the architect recommend? (Choose two.)

15. A customer wants to place their NSX Managers in different subnets.

Which would an architect recommend to support the request?


 