NetApp Certified Support Engineer – ONTAP Specialist NS0-592 Exam Dumps

How to prepare for NS0-592 NetApp Certified Support Engineer – ONTAP Specialist certification exam? NS0-592 exam is one hot NetApp topic, which is for NCSE-ONTAP Specialist certification to help candidates proven their skills in troubleshooting, analyzing, and remediating NetApp® ONTAP Storage Systems. Based on the exam objectives and skill measured, we have released new and latest NS0-592 exam dumps as your preparation materials. You can be successful in real NS0-592 NetApp Certified Support Engineer – ONTAP Specialist exam. 

Check NetApp NCSE-ONTAP Certification NS0-592 Free Dumps

1. A customer has created an interface group (igroup) named a0a, a VLAN named a0a-2500, and a data LIF associated with the VLAN interface that has been assigned an IP of 10.254.10.100. The customer is able to ping 10.254.10.100 from a Windows client without any issues, but data traffic is not working.

In this scenario, what is the solution to the problem?

2. You migrated from a FAS3250 system to a new A200 system. After the migration, you notice that data compaction fails to be enabled on the migrated volumes.

In this scenario, which statement is correct?

3. Click the exhibit button.

A customer has an FC SAN with brocade switches. Each server attached to the SAN gas four FC ports. The customer describes that one of their servers has only four paths to the LUNs configured on the cluster. There should be eight paths on all the other servers. The switch administrator has verified the zone configuration.

Referring to the exhibit, which two actions would you perform to troubleshoot the problem? (Choose two.)

4. Click the exhibit button.

When you log in to a node, a warning is displayed as shown in the exhibit.

Which statement is correct in this scenario?

5. You are running a fabric-attached MetroCluster configuration with ONTAP 9.5software. There is a maintenance window for the upcoming weekend. Plexes in your mirrored aggregates between your two data centers have not been synchronizing for two days.

When the resynchronizations begin, they are not as quick as expected, and the process takes more than a day.

You have been modifying the number of concurrent I/O streams using the storage raid-options modify raid. resync.num_concurrent_ios_per_rg command, but the resynchronization speed stays slow.

You have four separate ISLs between your data centers using Brocade 6510 switches.

Hardware problems are not an issue.

Which two actions should you take to prevent this problem in the future? (Choose two.)

6. Click the exhibit button.

Your customer is calling about their MetroCluster environment. They have provided you with the output of the metrocluster interconnect adapter show command.

Referring to the exhibit, which statement is correct?

7. Click the exhibit button.

The storage administrator for the company example.com is attempting to join an SVM to their Active Directory as SVM1. The computer account must also be joined to the Secure organizational unit. Attempts to perform this action using the CLI fail with the error message shown in the exhibit.

What is the reason for this error?

8. A reboot was performed by a watchdog reset on the node.

In this scenario, which statement is true?

9. In a 4-node MetroCluster cluster, both clusters are alerting that the connection to an ATTO bridge is lost.

Which three components should be verified to determine what is causing this problem? (Choose three.)

10. Your customer has initiated several volume move commands to redistribute the workload in their 8-node cluster. To verify that this process is not affecting their client access, they were monitoring the network switches that provide client access, but they do not see the network load of the volume move command.

In this scenario, what is the reason for the behavior?

11. Click the exhibit button.

Your customer reports that their FAS2554A system reports multi-path HA when running the sysconfig command. However, Config Advisor reports an error about incorrect cabling.

What are the two reasons for the messages? (Choose two.)

12. Click the exhibit button.

A customer reports that when they are failing over Hyper-V VMs, the process fails, and the server reports an error that indicates that there is something wrong with the storage.

Referring to the exhibit, which three actions would be required in ONTAP to solve this problem? (Choose three.)

13. Click the exhibit button.

Many end users are complaining that logging in their systems takes a long time. When the login to the desktop finishes, everything is fine. The home directories are on NetApp storage. You do not see any significant disk or CPU contention on the controller, so you gather output statistics from the controller and focus on SMB.

Referring to the exhibit, which two actions would help diagnose the problem? (Choose two.)

14. Click the exhibit button.

A customer is reporting that numbers in the statistics volume show command output appear to be incorrect.

Referring to the exhibit, which statement is correct?

15. Click the exhibit button.

You have just cabled a new shelf to a FAS8200. Running the system node run -node * sysconfig - a command indicates that multipath HA is configured. However, after running Config Advisor, you receive an error that your cabling is incorrect.

As indicated in the exhibit, which two actions will correct the cabling? (Choose two.)

16. Click the exhibit button.

You are troubleshooting a system in which the customer reports that aggregates on Stack 6c/12b are having slow response tomes from system NETAPP1CLUS-02.

Referring to the exhibit, which two statements are correct? (Choose two.)

17. Click the exhibit button.

Referring to the exhibit, which change is required to enable the CIFS Autolocation function for the Users share?

18. A customer reports that a LUN is offline because the volume is out of space even though the space-reserve parameter is configured to enabled on the LUN.

Which two statements are correct in this scenario? (Choose two.)

19. Click the exhibit button.

A storage administrator reports that when they enabled Vscan, they began receiving reports of CIFS users having very slow access to all their files. The storage administrator recovered from the issue by disabling Vscan on their SVM. The storage administrator was able to collect perfstat output during the time of the reported slow access, as shown in the exhibit.

In this situation, what is the problem?

20. A customer reports that a takeover has been disabled on an HA pair.

What would be a cause for this to happen?


 