Dell PowerEdge Professional Exam DCPPE-200 Dumps Questions

Dell PowerEdge Professional Exam DCPPE-200 is the requirement for Dell Certified Professional – PowerEdge certification. The certification validates the ability to perform intermediate to advanced skill level tasks in deploying Dell EMC PowerEdge Server products. Make sure you will choose valid and correct Dell PowerEdge Professional Exam DCPPE-200 Dumps Questions to prepare for Dell PowerEdge Professional Exam. Passing DCPPE-200 exam should get 700 score out of 900, and great DCPPE-200 Dumps Questions from DumpsBase can help you achieve this goal.

Without any worries, just check DCPPE-200 free questions of DumpsBase DCPPE-200 Dell PowerEdge Professional Dumps questions for the quality.

1. An engineer is installing two PCIe NICs into an existing VRTX chassis. Node 1 has three PCIe cards assigned to it already. After installation, the engineer is unable to assign the two new NICs to node 1.

What should the engineer do to assign the two PCIe NICs to node 1?

2. A VRTX server comes with two server modules. The customer requests to assign three PCIe Adapters per each server module. While performing this configuration, the engineer is unable to assign more than two PCIe Adapters per server module.

What is the cause of this issue?

3. An engineer deploys an FX2 and plugs cables from GB1 and STK/GB2 into the management network switch for path and NIC redundancy. When the chassis is powered up, the management network is adversely affected.

What should the engineer do to fix this issue?

4. An engineer is deploying a new server node into an existing chassis for a virtualization cluster. The existing cluster nodes have many modified BIOS settings to meet workload needs.

How should the engineer quickly deploy the new server node with matching BIOS settings?

5. An engineer needs to limit the power consumption of a chassis without powering down any server nodes.

Which step should the engineer take to perform this task?

6. Enclosure level backup

Which license type is required?

7. An engineer is troubleshooting a blade server in an FX2s. The compute sled in SLOT 3 will NOT power on. The engineer has taken the server down to minimum to POST. The server still does NOT power on. The engineer then swaps sleds SLOT 2 and 3. The iDRAC initializes in SLOT 2 but SLOT 3 is stuck at initializing the iDRAC.

What are two possible sources of the issue? (Choose two. )

8. A customer has five VRTXs in a chassis group that they need to disband. The engineer disbands the chassis group from the group leader, but a networking interruption prevents two of the VRTXs from getting the signal to leave the group.

What should the engineer do to finish disbanding the chassis group?

9. An engineer has a new blade chassis that is ¾ full. The chassis has six power supplies. The chassis at peak power usage needs at minimum four power supplies. Redundancy is NOT a concern.

The engineer needs a policy to meet the current needs and provide enough power to a fully populated chassis.

Which policy should the engineer choose?

10. An engineer is running an inventory report on a VRTX chassis group for a customer. When the engineer views the report, the engineer notices the inventory of one of the VRTX is missing one of its nodes.

What is the cause?

11. An engineer has been given a new chassis and needs to configure the iDRACs on all servers prior to deploying an OS on them. The iDRACs need to be configured with IP addresses and a new root password.

What is the most efficient method to perform this task?

12. An engineer has connected a monitor, keyboard, and mouse to a VRTX chassis. The engineer is unable to see or control the first blade.

What must the engineer do to control the first blade with a connected monitor, keyboard, and mouse?

13. An engineer needs to replicate BIOS and NIC settings for server nodes installed in the chassis.

Which CMC feature should an engineer use to perform this task?

14. A password to the CMC root account on an M1000e server chassis has been misplaced.

What should be done to restore administrative access to the CMC?

15. An engineer responsible for server lifecycle management (e. g. Monitor, Update, Deploy) needs to build a monitoring strategy for a multi-vendor data center. The company has an established third party software as the monitoring and help desk system.

Which option should be used to integrate Dell Server hardware into this monitoring architecture?

16. An engineer needs to update BIOS in the following environment:

- Over 100 servers are spread over 10 chassis

- All servers are in the same data center

- The only maintenance window is late Sunday evening when OS patches are applied and servers are rebooted

- Less than 10 minutes of additional downtime per server is allowed

What is the most effective update strategy?

17. An engineer is responsible for data center bare metal deployment. The engineer deploys hundreds of servers each week and must repeatedly deploy a standard hardware (HW) configuration and put the OS on the bare metal servers.

How should the engineer automate some of these tasks?

18. An engineer needs to perform hardware configuration, including RAID, on a new batch of 30 identical server nodes. OpenManage Essentials is installed, and the sever nodes have been discovered via iDRAC.

The engineer needs the most efficient way to replicate the configuration from a single configured system without losing connectivity to the iDRAC.

How should the engineer perform this task?

19. An engineer configures an Alert Action in the CMC to send an email on Warning and Critical events. Chassis fan and power events are showing up as expected. Server-specific failures such as memory module failures only indicate that the server has gone into a Critical or Warning state.

What additional configuration needs to be done to be informed via email of the detailed server failure?

20. An engineer needs to use OME to monitor 4000 servers in the environment.

Which two tasks should the engineer perform to improve OME performance and scalability? (Choose two. )

21. An engineer is updating the IOM Infrastructure Device firmware from the CMC GUI. The IOMINF device is NOT listed as a device that can be updated.

What is causing this issue?

22. An engineer is performing system updates on a large number of systems using OpenManage Essentials. The engineer has been instructed NOT to update network adapter firmware at this time.

How can the engineer exclude a firmware update while still using the Dell Online Catalog source?

23. An engineer is deploying Dell SupportAssist to manage a data center.

After downloading and installing Dell OpenManage Essentials with SupportAssist, which two steps must be done to complete this task? (Choose two. )

24. Company servers are in the branch offices located at different geographic locations. All servers are running ESXi hypervisor. The are no network connections between the branch office and central office.

What is the most cost effective way to update firmware in each location?

25. An engineer needs to enable automated proactive support from Dell for ProSupport entitled assets discovered in OpenManage Essentials.

What additional software should the engineer install?

26. A new M1000e is being deployed in the data center. All initial power and data cabling is complete. The engineer checks the CMC Chassis Health and sees that one of the six PSUs displays as Failed (No AC). An AC cable is connected, and the power distribution unit produces good AC output.

What two tasks should be completed to troubleshoot this issue? (Choose two. )


 

 

 

Valid VMAX3 Solutions (SA) E20-507 Exam Dumps Free Download
Real VMAX All Flash and VMAX3 Solutions E20-807 Practice Questions

Add a Comment

Your email address will not be published. Required fields are marked *