Dell PowerEdge Operate 2023 D-PE-OE-23 Exam Preparation Materials: D-PE-OE-23 Dumps Online

The D-PE-OE-23 Dell PowerEdge Operate 2023 certification exam is a key step in validating your ability to perform intermediate skill-level tasks in installing, configuring, maintaining, and troubleshooting Dell PowerEdge Server products. To ensure your success in the challenging D-PE-OE-23 exam, DumpsBase offers the latest D-PE-OE-23 dumps with valid, updated, and actual D-PE-OE-23 exam practice questions. The Dell PowerEdge Operate 2023 D-PE-OE-23 exam dumps offered by DumpsBase are meticulously designed by qualified and experienced exam experts, who work tirelessly to ensure that the D-PE-OE-23 exam dumps are the first choice for you aspiring to excel in your Dell PowerEdge Operate 2023 certification journey. By utilizing DumpsBase D-PE-OE-23 exam dumps, you not only ensure success in your exam preparation but also gain the confidence to excel in the Dell PowerEdge Operate 2023 certification exam on your first attempt.

Dell PowerEdge Operate 2023 Certification Exam D-PE-OE-23 Free Dumps

1. A technician wants to remotely log in to a server but finds that the IDRAC virtual Console feature Is not available. Use the simulator to explore the system.

What Is the cause of this Issue? Note: It is necessary to dose (x) the simulator window before you can select a response to this question.

2. What is a requirement to operate GPUs in a Dell EMC PowerEdge R740 server?

3. What happens when the Hardware Root of Trust fails to validate the BIOS?

4. A technician receives a new server with five drives.

They need to configure the drives based on the following requirements received from the administrator:

- Drive 0 as a single disk with no RAID

- Drives 1-3 as a RAID 5 with drive 4 as a hot spare just for this newly created RAID 5

The administrator plans to add more disks as separate RAID arrays at a later date but only wants drive 4 to be available for this first RAID 5 set.

How should the technician configure the drives?

5. A technician must update the firmware on a savor, but has no network connectivity.

What can the technician use to update the BIOS and iDRAC/ lifecycle Controller firmware?

6. A Dell EMC PowerEdge server has been updated with an LCC and iDRAC DUP to the latest firmware when performing a firmware rollback?

7. A technician wants to configure the iDRAC on a new server using the iDRAC Quick Sync 2 feature.

What is required to use this feature?

8. Which is responsible for controlling the NVMe disks, when using a Paddle Card in a PowerEdge 15G server?

9. A technician needs to configure a server to allow the OS to manipulate processor frequencies for higher power efficiency.

Which setting can they enable to achieve this?

10. How can a system administrator compare the currently installed hardware to the original system configuration?

11. A server has six memory modules attached to each CPU Memory Optimizer mode is configured. The user now wants to have maximum protection for the memory but cannot afford to lose any memory space.

What should the technician install/configure?

12. Where is the LCD panel located on a Dell PowerEdge 16G server?

13. A technician is trying to troubleshoot a server that constantly keeps raising and lowering the RPMs of the fans.

The technician investigates and finds the following:

- No errors are displayed

- No obvious log entries exist concerning temperatures

- Server cover is installed and secured

- No expansion cards are installed

What would be the quickest action plan that the technician could attempt to try to fix the issue with the fans?

14. A technician installs a PCIe card into a server, but the card does not appear in the OS. The server does not have an LCD to display errors, but a light is flashing on the front of the server.

What actions can the technician take to troubleshoot the issue?

15. What is the minimum number of components, beside the system board, required to POST?

16. Which export type in iDRAC restores a Server Configuration Profile to a known baseline?

17. A technician is setting up SNMP Trap Alerts on a 14G servers.

After specifying the trap destination address, what should be the next step?

18. A technician is installing Windows Server 2016 on a server with RAID 1 and RAID 5 virtual disks.

How should they configure the server and deploy the OS?

19. What is the maximum number of CPU cores that can be configured in a Dell EMC PowerEdge R6525 server?

20. A Dell EMC PowerEdge server logs the following CPU Machine Check error: CPU1 IERR.

What action might be required to solve the alert?

21. A technician needs to perform a RAID controller firmware update from within the Operating System. The server runs Red Hat Enterprise Linux and is configured with an iDRAC basic license.

Which three steps should the technician take to complete this task? (Choose three.)

22. A technician must create a RAID array that uses striping with double parity.

Which RAID level must be used?

23. A technician installs eight servers into a fully operational rack with top of rack switch Each server has a quad 1Gb NIC and redundant power supplies. The company uses iDRAC in shared LOM mode with LOM1 as the selected NIC.

What should the technician do to verify iDRAC connectivity on each server?

24. Which Dell PowerEdge 16G server has the highest GPU density to run workloads like HPC, AI, DB Analytics, and VDI?

25. A technician in Portland, Oregon has been asked to update the firmware on a server in Omaha, Nebraska. They will use an NFS server also located in Nebraska for serving patches that have been vetted by their security teams.

What two pieces of information does the technician need in order to access the NFS patch server from the Lifecycle Controller or iDRAC? (Choose two.)

26. A remote technician needs to update the iDRAC with Lifecycle Controller firmware using the iDRAC GUI. They have downloaded the iDRAC firmware to the management station and connected to the iDRAC GUI.

What step is required to complete this task?

27. A technician is investigating a server that is reporting that the Lifecycle Controller is disabled during the power-on procedure.

After checking that the system is displaying no other errors, how can the technician re-enable the Lifecycle Controller?

28. A technician wants to install a new version of OMSA onto a server that already has an existing version of OMSA.

What is required for this new installation?

29. Eight new servers have arrived at a datacenter. All use static IP addresses for iDRAC. The technician needs to enable these servers to contact the DHCP server on the network to obtain new IP addresses.

What method can the technician use to quickly switch to DHCP?

30. Which front disk chassis option is available in a Dell EMC PowerEdge R740 server?

31. You have been tasked with configuring a Dell EMC PowerEdge server to be a file server. The server operating system has been installed and there are 8 x 1TB drives that must be configured.

Which RAID configuration would provide the maximum usable space with maximum redundancy?

32. What type of fans are installed in servers with NVMe storage and GPU configurations?

33. What is used by the Lifecycle Controller to directly back up the server profile on a 14G Dell EMC PowerEdge server?

34. SPECIAL INSTRUCTIONS

The remaining Part1 questions are associated with four case studies that describe various environments or settings. Each case study appears on its own display screen. Questions for each case study will appear on separate display screens. When displaying a question, you can easily review the related case study by clicking on the 'Review Case Study' icon shown below:

Case Study 5 - Refer to the Exhibit.

Backing up data from a Dell EMC Isilon cluster exceeds the company's backup window. Because the company has a large amount of data with a continuous high growth rate, they want to change their backup strategy. The Gen 6 Isilon cluster consists of 24 nodes.

Their current backup strategy is an NDMP three-way backup performing weekly full backups to tape and incremental backups each night. The strategy uses Dell EMC Net Worker. The DMA uses Include paths to specify what data to backup. All data on the cluster must remain accessible.

The company's IT team is now looking for a method to increase the performance of their backups. After some investigations, you notice that the backup job quiesces the file system. This is creating lock contention issues on open files and not allowing users full access to data when the backup job runs.

What advice should be provided to the team to eliminate lock contention and allow full access to users?

35. Assign a new password

36. A technician is sent on-site to troubleshoot a server that halts during POST. The iDRAC System Event Log shows the following errors: A bus fatal error was detected on a component at bus 0 device 1 function 1 A bus fatal error was detected on a component at bus 1 device 0 function 0 CPU 1 has an internal error (IERR)

The following system information is provided.

Which system component is the most likely cause?

37. A system administrator plans to use a remote desktop that has the DRAC tools installed to run RACADM commands.

Which two CLI options must be in the RACADM command? (Select 2)

38. Which tool allows an administrator to remotely back up a PowerEdge server configuration to streamline server deployments?

39. Which three steps must a technician take prior to replacing a server component with blue tabs/release? (Choose three.)

40. How can a technician know whether IDRAC9 System Lockdown mode is enabled?

41. Which application reduces the manual effort to update 500 Dell EMC PowerEdge R750 servers?

42. An error occurs during data transmission between the CPU and DIMM.

Which feature in a Dell PowerEdge 16G server is responsible for fixing correctable memory errors?

43. What is the minimum version of ESXi that should be used to avoid potential issues writing to the SD cards when running ESXi 7 from an IDSDM?

44. A technician needs to connect a server to a network but the network switch has only two available network ports so only two network cables can be connected. The user needs as much bandwidth as possible for their workload so the two network cables need to connect to LOM1 and LOM2.

At some point in the future a new network switch will enable additional cables to be used. The technician wants to satisfy the user requirements yet still be able to access the iDRAC without having to reconfigure the iDRAC once new cables are installed in the iDRAC Dedicated NIC.

What is the best way to configure the iDRAC?

45. Which two iDRAC license editions support enabling the Lockdown Mode feature? (Select 2)

46. In which Dell EMC PowerEdge server generation was the BOSS card introduced?

47. What image does the iDRAC9 BIOS/UEFI Recovery feature use to flash a corrupt BIOS?

48. What operation should a technician perform to ensure configuration recovery if a server must be physically replaced?

49. A Dell PowerEdge R740 server with two CPUs has six memory modules that are attached to each CPU. Memory Optimizer mode is configured. The user now wants to have maximum protection for the memory but cannot afford to lose any memory space.

What should be installed or configured?

50. When does a customer require the Service Tag of the Dell EMC PowerEdge server?

51. A technician needs to install a server with a PERC RAID controller and 24, 2.5" SAS SED drives.

The installation requires the following items to be created:

- Three equal-sized virtual disks

- Encrypted virtual disks

- A global hot spare

In addition to selecting the physical drive to be the hot spare disk, what tasks should the technician perform to set up the RAID controller?

52. Refer to the exhibit.

Match each callout to the Dell EMC PowerEdge server model shown.

53. A technician deletes the iDRAC Enterprise license on a R640 server.

Which license type is then enabled?

54. Where is the Asset Tag located on the Dell EMC PowerEdge server?

55. A server has the following configuration:

- 5x 1 TB drives configured in a RAID 5 array

- 1x 1 TB as a global hot spare

- Persistent Hot Spare Slot enabled

A user adds one additional 2 TB drive to the existing array using RAID migration.

How much disk space is available to the operating system?

56. What is a systems management console solution optimized for monitoring and managing Dell enterprise and remote office hardware?

57. What is a valid password option available from the iDRAC9 Unique ID feature?

58. An administrator is troubleshooting a no power issue on his PowerEdge server. They have confirmed the cable is "known good," and the LED on the PSU is green.

What is the next step in troubleshooting this issue?

59. A technician needs to improve overall server performance. All servers run a Dell-supported version of RedHat Linux. Turbo boost has been highly beneficial. CPU performance should be maximized, but not at the expense of power usage.

What is the most efficient way to implement these profile options?

60. What are key characteristics of SupportAssist Enterprise on Dell EMC PowerEdge 14G servers?

61. A technician creates two virtual disks and assigns a dedicated hot spare to each virtual disk. The technician also creates a global hot spare. A drive fails on the second virtual disk.

What is the result?

62. What category of error is indicated by HWC8011?

63. What is the drive characteristic of a BOSS M.2 drive in a Dell EMC PowerEdge server?

64. One of the servers in a datacenter is set to use the 1+1 power redundancy option with a hot spare. The server uses 1100W PSUs. An SNMP trap has been sent alerting the technician to a PSU failure.

Since this is the "hot spare" PSU, the technician chooses an available, higher capacity Titanium PSU. After replacing the PSU and connecting the power cable, the PSU indicator/handle flashes green, then turns off.

The technician has taken the following actions:

- Reseated the PSU

- Checked the firmware version

- Checked the cable connections

The PSU continues to flash green then turn off.

What should the technician do?

65. A technician needs to troubleshoot a server. The OS was operational. After an untrained person accesses the System Setup utility on the server, the OS now fails to load.

The technician reboots the server, selects F2, accesses the System Setup utility, and selects System BIOS. The technician needs to verify items in the System BIOS settings before reloading the OS.

Which two items should the technician verify? (Choose two.)

66. A technician must use the iDRAC UI to roll back a diagnostics firmware revision on a server that was updated four weeks previously. However, the replaced version cannot be found in the Firmware Rollback section on the iDRAC UI.

What is the cause of this issue?

67. A technician has a server in production. The iDRAC SEL log indicates a possible issue with DIMMs A1 and A2. Firmware is up to date.

What is the most efficient way to troubleshoot this issue?

68. A company that has very specific firmware requirements has acquired Dell EMC PowerEdge servers Any replaced parts of the type must match the original parts identically. The procedure must be as simple as possible with minimal risk.

What action should a technician take to help accomplish this goal?

69. What is a custom form factor mezzanine card that contains a complete NIC subsystem?

70. A technician builds a bootable ISO with Repository Manager, and then mounts the ISO via the iDRAC virtual console. After the updates have completed, the technician reboots the server to apply the updates. When reviewing the updates, the technician determines NOT all updates were applied.

What is causing this issue?

71. A technician is changing the iDRAC IP address from the static IP address 10.37.125.88 to DHCP on the technician's PowerEdge R640 that does not have a front LCD. After completing this task, they are unable to determine which IP address was given to the iDRAC and they cannot reboot the server.

What method could the technician use to determine what IP address is assigned to the iDRAC?

72. What are two ways to check on the health status of a server? (Select 2)

73. What is the result when iDRAC is in Lockdown Mode?

74. Starting from which Dell EMC PowerEdge server hardware generation is the Micro SD card in the IDSDM/vFlash module supported?

75. While working on a Dell EMC PowerEdge R640 server, a technician accidently removes two fans at the same time.

What should happen to the server?

76. An existing server is transferred to a new location. When the iDRAC port is plugged into the network, it causes an IP conflict. The technician is directed to change iDRAC settings via the LCD Front Panel Display. There is NO option to make changes.

What is the most probable cause of this issue?

77. A technician receives a repurposed PowerEdge server. After racking and cabling the server, they attempt to log into the iDRAC but cannot do so. The default login account has been disabled.

What method can be used to enable the default login account?

78. What is the maximum number of local iDRAC users that can be created?

79. A technician needs to replace a server component with orange tabs/releases.

Which two steps should the technician take to complete this task? (Choose two.)

80. A technician installs a PCIe Host Bus Adapter in a server, powers on the server, then starts the Lifecycle Controller to update the adapter's firmware. Before starting the firmware update, they examine the Current Hardware Inventory. The Host Bus Adapter is not visible so it cannot be selected for a firmware update.

How should the technician address this issue?

81. What type of screwdriver is required to remove the processor heat sink module?

82. An engineer needs to upgrade a Dell EMC PowerEdge R440 server from a single PSU to dual PSU configuration. There are unused PSU modules from PowerEdge R430 and R420 servers available, and they have the same wattage ratings.

What should the engineer do to complete the task?

83. A server administrator needs to access the iDRAC8 default interface. They are not using DHCP. They open a web browser and prepare to enter an IP address.

What IP address should they use?

84. A technician needs to install the OS on a server remotely using iDRAC.

What is the minimum iDRAC license required to perform this task?

85. A technician needs to configure the Lifecycle Controller network settings with a static IP address. A limited number of static IP addresses are available for use.

Which previously assigned IP address can also be used for the Lifecycle Controller?

86. Which memory operation modes are supported for a Dell PowerEdge R660?

87. A technician has a 13G system that is giving NO video to a crash cart connected to the front VGA port. The LCD is NOT reporting any errors.

The system reports ‘CPU Resetting’ messages sporadically in the lifecycle log. The iDRAC runs an Express license. The technician needs to most efficiently determine if the system is completing POST despite the video issue.

Which two steps should the technician take to perform this task? (Choose two.)

88. A Dell EMC PowerEdge 13G server is being controlled through a secure port by iDRAC8.

What login connection options are available on server using a secure port?

89. A technician needs to analyze a server that is using more power than expected. The server is part of a cluster that runs jobs between 8 AM and 5 PM. The cluster is not used at other times of the day. The server runs an unsupported OS. Performance while jobs are running is a key consideration.

Which option should the technician choose from within System Profile Settings within System Setup to address this issue?

90. Case Study 1

A company has several independent business units that operate globally. The company has consolidated its IT infrastructure services and operations. Common infrastructural services which include IPAM, DNS, NTP, DHCP, and SMTP have been consolidated.

The company has complimented its infrastructure development by investing in Dell EMC Isilon clusters to host its user's home and group directories and for compliance archival purposes required by individual business units. The IT operations are located in India and the United States with its primary data center facilities co-located between New York and Texas.

The company has a total of 60 AD forests:

- 1 main domain

- 55 domains have one-way trust relationships with the main domain

- An additional 4 domains do not have any trust relationship with no future plans of establishing trust relationships with the other domains.

Users of different AD domains use different FQDN to access their corresponding file services. Additionally, the company does not plan to consolidate the AD domains and each domain uses a different IP subnet.

The users of the domains with no trust relationships have a compliance archival requirement. The company wants to all data to be replicated between New York and Texas.

How many tenant Access zones will be required?

91. A technician needs to update the iDRAC license on a PowerEdge R740 server from Express to Enterprise.

The server has the following components:

- 2x CPUs

- 384 GB RAM

- 6x 1 TB drives

- 1x PSU

The server is powered down but connected to active AC. The user wants it to stay powered down and not connect to any networks. No errors are presently displayed.

How can the technician upgrade the license?

92. Where is the data stored to allow Easy Restore to successfully complete a system board replacement?

93. Beginning with which generation Dell EMC PowerEdge server is the NDC available?

94. A user installed OME on a PowerEdge R640 server. OME has discovered and is currently monitoring another 30 remote PowerEdge 14G servers.

Each server has the following configuration:

- 2x CPUs

- 384 GB RAM

- 6x 1TB drives in a RAID 6 virtual disk

- No hot spare drive

- PERC

- vFlash

- iDRAC9 Express license

At 9 PM on Monday evening, one of the remote servers has a disk failure but stays operational. The administrator monitoring OME does not find out about the issue until 5 PM in the following Friday. They place a support call to investigate why OME was not informed about the disk failure before then.

What is the reason for this issue not being reported to OME?


 

 

The Dell PowerProtect DD Deploy 2023 D-PDD-DY-23 Exam Dumps: Enhancing Your Expertise in Data Protection and Management
Achieve Success in the Dell Midrange Storage Solutions Design 2023 Certification: D-MSS-DS-23 Real Dumps Are Online

Add a Comment

Your email address will not be published. Required fields are marked *