Network Appliance NS0-593 Dumps Updated To Ensure Your NetApp Certified Support Engineer ONTAP Specialist Exam Success

Shamiyo 09-08-2022

For anyone who is planning to take the NS0-593 NetApp Certified Support Engineer ONTAP Specialist certification exam, we highly recommend choosing the Network Appliance NS0-592 dumps from DumpsBase as the learning material. No need to do others, just practice all those NS0-593 dumps questions and answers regularly to make sure that you can answer the true NetApp Certified Support Engineer ONTAP Specialist NS0-593 exam smoothly. Network Appliance NS0-593 dumps of DumpsBase include the pdf file and software, you can come to DumpsBase to download the NS0-593 exam dumps pdf file to start learning all those NS0-593 exam questions and answers thoroughly. The software is free and will be shared by mail. You can install the DumpsBase NS0-593 exam dumps software and practice the Q&As in a real exam mode. DumpsBase is thought of as among the top options to prepare for the NS0-593 exam mainly because they offer high-quality NS0-593 dumps to ensure your NetApp Certified Support Engineer ONTAP Specialist exam success.

Know NS0-593 NetApp Certified Support Engineer ONTAP Specialist Exam Details Clearly First

All DumpsBase NS0-593 dumps questions and answers are available to help you pass the NetApp Certified Support Engineer ONTAP Specialist certification exam successfully. Before downloading the Network Appliance NS0-593 exam dumps pdf file, you need to know all the Network Appliance NS0-593 exam details clearly first. The NS0-593 exam is one popular Network Appliance certification exam, which is for the NetApp Certified Support Engineer – ONTAP Specialist certification. Being a NetApp Certified Support Engineer – ONTAP Specialist, you have proven skills in troubleshooting, analyzing, and remediating NetApp® ONTAP Storage Systems.

How to earn the NetApp Certified Support Engineer – ONTAP Specialist certification?

First, candidates and students are required to have an active NetApp Certified Support Engineer (NCSE) certification. This certification proves that you have proven support skills with NetApp ONTAP and have experience supporting NetApp storage solutions. You are also able to perform general troubleshooting, root cause analysis, hardware replacement, system configuration, and software and firmware upgrades for NetApp storage solutions. Earning the NetApp Certified Support Engineer (NCSE) certification requires passing the Network Appliance NS0-194 exam successfully. To all, DumpsBase also has the latest NS0-194 exam dumps questions to be your great preparation materials. 

Then, they need to pass the NS0-593 exam for their NetApp Certified Support Engineer – ONTAP Specialist certification. The actual NS0-593 exam contains 60 questions, candidates will have two hours to complete all these questions. In countries where English is not the native language, candidates for whom English is not their first language will be granted a 30-minute extension to the allotted examination completion time.

Understanding the NS0-593 exam topics should be an important step to clear the NS0-593 NetApp Certified Support Engineer ONTAP Specialist exam. This exam tests your skills in the following domains:

● ONTAP OS

● Hardware

● Protocols

● Performance

● Software-defined ONTAP Solutions

Network Appliance NS0-593 dumps of DumpsBase are based on these exam topics, most successful candidates have verified the exam questions and found they are covered. We guarantee that with the updated NS0-593 exam dumps of DumpsBase, you can complete the NetApp Certified Support Engineer ONTAP Specialist exam successfully. 

Check The NS0-593 Exam Dumps By Reading The NS0-593 Free Demo

Before downloading the NS0-593 exam dumps pdf, you can read the NS0-593 free demo first:

After expanding a two-node AFF A300 cluster with two AFF A700 nodes, you observe latencies when data is accessed indirectly. The system node run -node -command netstat command shows retransmits and packet drops on the LIFs. The AFF A700 nodes with 40 Gbps and the AFF A300 connect with 10 Gbps to the cluster interconnect. You are using Cisco Nexus 3132Q cluster interconnect switches. You just updated to ONTAP 9.8 software.

In this scenario, what is causing this problem?

A. The 10 Gbps to 10 Gbps cluster Interconnect is creating a speed mismatch.

B. AFF A300 and AFF A700 node mixing Isnot supported in ONTAP 9.8 software.

C. The AFF A300 Is using an adapter card for the cluster Interconnect, but only onboard ports are supported.

D. There is an NXOS firmware mismatch, verify in the Interoperability Matrix (1MTJ for a supportedversion.

Answer: A

You created a new NetApp ONTAP FlexGroup volume spanning six nodes and 12 aggregates with a total size of 4 TB. You added millions of files to the FlexGroup volume with a flat directory structure totaling 2 TB, and you receive anout of apace error message on your host.

What would cause this error?

A. The maximum number of volume constituents has been reached in the ONTAP software.

B. All constituent volumes are full.

C. The inode limit is exceeded in the ONTAP software.

D. The maxdirsize Is exceeded in the ONTAP software.

Answer: C

A customer's storage administrator Informs you about the deactivated Automatic Switchover (AUSO) feature on their MetroCluster IP environment.

What Information would you tell your customer in this scenario?

A. The AUSO feature cannot be activated due to a non-mirrored aggregate.

B. The AUSO feature is not available in Metrocluster IP installations by design.

C. A faulty link automatically deactivated the AUSO feature.

D. This is a configuration failure, you can activate that feature for the customer.

Answer: A

A system panic due to an "L2 watchdog timeout hard reset" error occurred. You have found a FIFO message in the SP log.

Which FIFO message Is useful for Investigating this Issue?

A. before NMI BBSP:C=00 L=00 FIFO: F3 F2 F1 F0 5 B2 0 0 0 80 20 E F E3 C0 C2 3 4 6 7 9 9 A

B. BIOS exit BBSP:C=2F L=20 FIFO: 2 C8 C9 C4 24 4 6 18 7 8 11

C. before Reset BBSP:C=00 L=00 FIFO:

D. ONTAP Shutdown BBSP:C=00 L=2F FIFO:

Answer: B

You have a customer complaining of long build times from their NetApp ONTAP-based datastores. They provided you packet traces from the controller and client. Analysis of these traces shows an average service response time of 1 ms. QoS outputconfirms the same. The client traces are reporting an average of 15 ms in the same time period.

In this situation, what would be your next step?

A. The cluster is responding slowly and requires further investigation using performance archives.

B. The client that reports high latency should be investigated.

C. The cluster interconnects should be investigated.

D. A sync core should be triggered.

Answer: B

You receive the "Unable to connect to the management gateway server"error when trying to connect to a node management IP.

In this situation, how do you determine whether core dumps are generated for the mgwd user space process?

A. Log in to the nodeshell using the node console and collect the core dumps from the nodeshell.

B. Log in to the service processor and collect the core dumps from the service processor.

C. Log in to the clustershell using the node console and collect the core dumps from the clustershell.

D. Log in to the systemshell and collect core dumps from thesystemshell.

Answer: B

Your customer mentions that they have accidentally destroyed both rootaggregates in their two-node cluster.

In this scenario, what are two actions that must be performed? (Choose two.)

A. Rejoin the second node to the re-created cluster.

B. Re-create the cluster from the local backup.

C. Install ONTAP from a USB device.

D. Re-create the cluster from the remote backup.

Answer: A,C

Which two automation methods does NetApp ONTAP Select support? (Choose two.)

A. REST

B. Anslble

C. Docker

D. PHP

Answer: A,B

You notice poor performance on your FlexGroup and execute the system node run -node * flexgroup show command for more Information. You notice the "Urge" column has non-zero values.

In this scenario, which statement is true?

A. The aggregate is completely full.

B. The constituent volumes are out ofInodes.

C. The data placement is uneven.

D. The constituent volumes are completely full.

Answer: A

You have a new VMware vSphere cluster with ESXI 7.0U2 hosts. The hosts are connected to a 4-node AFF A400 NetApp ONTAP9.8 cluster with FC LUNs. You have a requirement to identify and follow I/Os from each VM on the shared FC LUN-backed datastores for troubleshooting purposes.

In this scenario, which VMware feature Is supported by ONTAP software to accomplish this task?

A. Network I/O Control (NIOC)

B. Virtual machine ID (VMID)

C. Storage I/O Control (SIOC)

D. vSphere Cluster Services (vCLS)

Answer: D