High-Quality CFPS Dumps (V8.02) for Your NFPA Certified Fire Protection Specialist (CFPS) Certification Exam

The Certified Fire Protection Specialist (CFPS) is great to increase your professional standing and promote the discipline of fire protection and prevention. Recognized as the gold standard globally for fire protection certification, the CFPS certification will help you be dedicated to reducing fire loss proving your education and experience. To pass the CFPS exam successfully, you can choose the high-quality CFPS dumps (V8.02) from DumpsBase as the learning material. These newest dumps are created by professionals and contain the most up-to-date information relevant to the Certified Fire Protection Specialist (CFPS) certification. By using the high-quality CFPS dumps, creating a structured study plan, and practicing regularly, you can significantly increase your chances of passing the Certified Fire Protection Specialist (CFPS) exam on your first attempt.

Check CFPS Free Dumps to Verify the High-Quality Certified Fire Protection Specialist (CFPS) Dumps

1. Which of the following would NOT be an appropriate purpose for employing a guard service to protect a property against fire loss?

2. Which type of construction consists of structural members of approved noncombustible or limited combustible materials with specified fire resistance ratings for exterior bearing walls of 3 or 4 hours?

A. Type I

B. Type II

C. Type III

D. Type IV

3. Which foam extinguishing agent can be proportioned into final concentrations of 1%, 3%, and 6%?

4. The two major principles used to determine egress width are the

5. The goals of the first edition of NFPA 13D were to provide sufficient time for safe egress or rescue, economic viability, and

6. The ignition temperature of acetylene gas is

7. Zebra mussel pipe obstructions are largely concentrated around the Great Lakes and

8. Which factor plays a significant role in most industrial fire and explosion losses?

9. When evaluating the hydraulic properties of water for fire protection system, what is the measurement of a fluid's resistance to flow?

10. What type of smoke management method is referred to as smoke purging, smoke removal, smoke exhaust, or smoke extraction?

11. Typical fire pump drivers reach maximum brake horsepower between

12. Potassium bicarbonate is a dry chemical agent considered to be twice as effective as

13. The primary design approach to mitigate the effect of wind on smoke movement in high-rise buildings is based on

14. Response Time Index (RTI) is a value applicable to

15. All of the following must be demonstrated to prove professional negligence under standard of care EXCEPT

16. The ignition test method that exposes the specimen to a known heat flux from a tungsten-quartz heater is referred to as a

17. What type of fire pump has a pressure range that can exceed 300 psi (2,068 kPa)?

18. Which OSHA regulation addresses storage and handling of liquefied petroleum gas?

19. When using the Fire Safety Concept Tree to assess life safety for occupancies, the major categories of strategies include managing the fire, managing exposed occupants, and

20. Environmental Protection Agency standards require solid waste be treated as hazardous if it is a listed waste and/or meets the characteristics prescribed by the standard for toxicity, reactivity, corrosivity, and

21. The primary mechanism by which carbon dioxide extinguishes fire is

22. Which type of plan review may provide information about a modification such as the removal of an abandoned underground flammable liquid tank?

23. Sound meters used to test notification appliances in fire alarm systems shall comply with which standard?

24. When using water mist as an extinguishing mechanism, the effectiveness of a fine mist depends on

25. Fire alarm systems audible appliances ratings are usually stated as a sound pressure level (SPL) at what distance?

26. Which type of roof covering is most effective in preventing the spread of fires from flying brands?

27. The minimum carbon dioxide design concentration for extinguishment of an ethylene fire is

28. What data analysis approach provides the broadest perspective of a fire problem?

29. Heat transfer oils can be used up to

30. Which pure metal in its solid form in oxygen has the highest ignition temperature in degrees Fahrenheit?

31. When should the data of a pre-incident plan be evaluated?

32. For wet-pipe automatic sprinkler systems, the only proper way to test the operation of a vane-type water flow alarm initiating device is to open the

33. Panic hardware devices are designed to facilitate the release of the latching device on a door with a pressure note xceeding

34. Fire tests typically relate to two types of fire properties, fire resistance and

35. Explosions or fires from flammable gas or oil fuel vapor-air mixtures may be prevented by ventilation and controls that keep the flammable vapor content below what percent of the lower flammable limit of the vapor-air mixture?