Huawei H13-629_V3.0-ENU Dumps (V9.02) – Get Valid Study Materials to Prepare for the HCIE-Storage (Written) V3.0 Certification Exam

Looking to pass the HCIE-Storage (Written) V3.0 certification exam? DumpsBase offers the latest H13-629_V3.0-ENU exam preparation materials. Our recently updated V9.02 package includes 1,323 questions and answers to help you prepare for the Huawei HCIE-Storage (Written) V3.0 certification exam. These H13-629_V3.0-ENU materials are compiled by experienced experts who know the exam center thoroughly, ensuring high-quality content. The updated materials cover essential exam topics comprehensively, allowing you to master key concepts through practice. Our exam questions are based on verified professional experience, and when you purchase our H13-629_V3.0-ENU exam materials, you’ll receive free access to our updating system. Choose DumpsBase’s H13-629_V3.0-ENU exam dumps (V9.02), we guarantee that you will pass your Huawei HCIE-Storage (Written) V3.0 certification exam successfully.

Check our free dumps to verify the updated H13-629_V3.0-ENU dumps (V9.02):

1. The customer needs to create a new OLAP backup database for batch import of online database data at night. The data file capacity is about 20TB. The storage array is Huawei OceanStor hybrid flash storage. The stable write bandwidth is required to reach 1800MB/s. Which of the following configurations best meets the customer's requirements?

2. In Huawei's active-standby disaster recovery solution, Oracle RAC clusters are deployed at production sites to ensure that the disaster recovery database application can still provide services normally when a production-side failure occurs. Which of the following statements is correct?

3. Huawei OceanStor all-flash storage system supports IP drift to ensure business continuity and reliability. Which of the following statements about IP drift is wrong?

4. The customer's business is very important and has a large amount of data. The customer needs the best possible business continuity. At the same time, the customer needs to be able to provide services to the outside world even when encountering natural disasters (floods/earthquakes). If you were asked to design a disaster recovery network, which network would you choose?

5. Huawei's all-flash storage system automatically adds all Ethernet ports and bonded ports in the cluster to which of the following drift groups?

6. A customer plans to build a disaster recovery center that can take over production business after the production center fails. The customer's business attributes can tolerate a 2-hour business suspension. The disaster recovery center is 50KM away from the production center. The customer requires that the production center and the disaster recovery center adopt 1 mode and provide convenient disaster recovery management.

Regarding the description of the customer's disaster recovery center construction needs, which of the following statements is wrong?

7. A company purchased a set of Huawei hybrid flash storage. The host is connected to the storage through a fiber optic switch. When planning the configuration of the fiber optic switch, which of the following options is the best configuration?

8. A company plans to deploy a disaster recovery system, requiring that when a data center-level failure occurs, the business will not be interrupted and the business data will not be lost. It plans to use a two-site three-center interconnection frame. Which of the following solutions can meet the requirements?

9. Which of the following statements is correct about the multi-NameNode feature of Huawei's distributed storage products?

10. In the Huawei OceanStor 9000 version, in order to experiment with unified management of the video surveillance functions of multiple Huawei OceanStor 9000 products, it is necessary to install the UniformView software. Which of the following description is wrong?

11. A multinational enterprise has a huge business, and its customer business data is scattered in multiple locations, with the distance between each location greater than 1000km. The enterprise hopes to centrally manage the backup data of each site, so that users can analyze and mine all data without affecting normal business. In addition, if any business site suffers a disaster, the enterprise can take over the business and perform data recovery.

In this case, which disaster recovery backup solution should the enterprise choose?

12. A customer's Huawei OceanStor hybrid flash storage array has a damaged controller and needs to replace the controller. Shortly after the on-site engineer replaced the controller, he found that the alarm indicator of the newly inserted controller was red and there was an audible alarm. How should the on-site engineer handle it correctly?

13. M Company plans to build an off-site disaster recovery center with a disaster recovery distance of 1000KM. The company's daily business growth is 2GB, the data synchronization time is up to 8 hours a day, and the bandwidth utilization rate is about 70%.

In this scenario, what is the minimum network bandwidth required to meet the demand?

14. A company's business host runs the Linux operating system (CentOS for example). When a storage engineer collects performance data, he needs to use a Linux system performance monitoring tool. Which of the following operations is wrong?

15. Bank A uses Huawei's hybrid flash storage to build a 3DC multi-site disaster recovery solution. Which of the following options are correct regarding the advantages of this solution? (Multiple choice)

16. Customer F plans to purchase Huawei's data protection appliance to protect the production system. The customer's current business status is as follows: The system's business peak time is 9:00-18:00 on weekdays, and the customer requires that the backup time be reduced as much as possible. The business data is a small file, but the total capacity is large.

Based on this scenario, when formulating a backup strategy using Huawei's integrated data protection device, which of the following statements is correct? (Multiple choice)

17. The source end is a third-party storage device and the target end is Huawei OceanStor hybrid flash storage. What are the current migration solutions? (Multiple choice)

18. Huawei's heterogeneous virtualization migration solution uses the SmartMigration feature of storage. What are the main benefits of this feature? (Multiple choice)

19. An archive is going to expand the storage system of its data center. During the capacity planning process, engineers need to consider not only data capacity, file system, RAID level, hot spare space, safe disk, value-added features, etc., but also capacity deviations between hard disk manufacturers and operating systems.

20. Huawei OceanStor storage system asynchronous remote uses multi-time slice cache technology to make the RPO index of LUN asynchronous remote reach seconds.

21. In Huawei OceanStor hybrid flash storage, the data, logs, and modification information of a database application are stored in the primary LUDN1, primary LUN2, and primary LUN3 respectively, and asynchronous remote replication is created for the three primary LUNs. When the primary LUIN2 fails, the database can be started normally through the primary storage system after the data of the primary storage system is restored using the secondary storage system.

22. In the OceanStor 9000 system, the InfoEqualizer partition cannot be P.

23. Distributed storage can be used as an independent network element to connect to eSight and OceanStor services.

24. Distributed storage, file storage and object storage can share storage space with block storage and switch freely.

25. When building a large-scale FC storage network, you will encounter the scenario of FC switch cascading, when multiple FC switches are cascaded.

Which of the following scenarios will cause the switch to isolate the E Port? (Multiple choice)

26. Which of the following businesses can use SmartTier features to improve storage system performance and reduce user costs? (Multiple choice)

27. Which of the following statements about Thin LUN are correct? (Multiple choice)

28. Which of the following descriptions of high-performance technology in HyperMetro is correct? (Multiple choice)

29. Which of the following descriptions of HyperMetro's arbitration server mode is wrong? (Multiple choice)

30. A customer's business application uses a Huawei OceanStor hybrid flash storage system with three pools, all of which are 8D+1P RAID5. One day, a business interruption occurred, and engineers found some scenarios that caused the failure by analyzing the logs.

Which of the following scenarios will cause interruption of host access to storage services? (Multiple choice)

31. A company's business runs on a Linux system (with a Linux 2.6 kernel) and is connected to storage via ISCSI. Engineers tested and found that the read and write bandwidth of the host accessing the storage is very low, causing application stalls and read and write errors.

Which of the following actions would help resolve the issue in this scenario? (Multiple choice)

32. A company purchased a set of Huawei storage (such as Huawei OceanStori hybrid flash memory) equipment, which uses a hard disk with a SAS interface. In addition to SAS hard disks, what other types of hard disks can this storage support? (Multiple choice)

33. The customer replaced the old storage based on volume migration. Which parts need to be checked and verified before officially launching the business? (Multiple choice)

34. Which of the following statements are correct about the high reliability architecture of Huawei's all-flash storage? (Multiple choice)

35. Which of the following statements are correct about the protocol layer of Huawei's distributed storage products? (Multiple choice)

36. Regarding the remote technology of Huawei OceanStor all-flash storage, which of the following options are features that it can support? (Multiple choice)

37. Regarding the file system quota feature of Huawei OceanStor hybrid flash storage, which statement about Quota Tree is correct? (Multiple choice)

38. For various types of storage product portfolios, Huawei has launched a series of data management software to support the management and operation of different storage. Which of the following data include? (Multiple choice)

39. Which of the following are common high-risk operations under Linux? (Multiple choice)

40. Large e-commerce company A uses Huawei hybrid flash storage to ensure its core business. Which of the following statements are correct about the SSD storage chip technology? (Multiple choice)

41. OceanStor 9000 provides directory-level snapshots. What are the application restrictions of snapshots? (Multiple choice)

42. Which of the following statements about the InfoEqualizer feature of the OceanStor 9000 storage system is correct? (Multiple choice)

43. What are the application scenarios supported by LUN migration? (Multiple choice)

44. An enterprise has an online transaction system and an email system in a 30 TB storage resource pool. The backup system has created three 10 TB Thin LUNs. Since the company is just starting out, the online transaction system and the email system have very little data. The backup system needs to import about 20 TB of old data, which exceeds the Thin LUN size, resulting in write failure.

45. SmartMatrix3.0 architecture is a multi-controller interconnected system architecture designed by Huawei for enterprise-level data center core storage systems. Based on the SmartMatrix3.0 principle, Huawei OceanStor 18000 can support up to 16-engine (32 controller) clusters.


 

Huawei H13-211_V3.0-ENU Dumps (V8.02) - Completing Your HCIA-Computing V3.0 Certification Exam with the Latest H13-211_V3.0-ENU Exam Questions 2025

Add a Comment

Your email address will not be published. Required fields are marked *